Hvac 108 Exam Questions With Correct Answers
Combustion air for an oil burner is provided​ by_____. - ANSWER-a combustion air fan 
 
The output of the ignition transformer​ is_____. - ANSWER-10,000 volts 
 
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. - ANSWER-two 
 
When reviewing the...
- Package deal
- Exam (elaborations)
- • 1 pages •
Combustion air for an oil burner is provided​ by_____. - ANSWER-a combustion air fan 
 
The output of the ignition transformer​ is_____. - ANSWER-10,000 volts 
 
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. - ANSWER-two 
 
When reviewing the...
Oil Electric Final Exam Questions & Answers(GRADED A+)
The heat anticipator in a thermostat is adjusted by the millivolts of the secondary circuit: T or F - ANSWER-True 
 
In MA 527CMR4.00 all electrical safety switches are wired in series: T or F - ANSWER-True 
 
A power venter is an electrically operated mechanical fan to exhaust combustion gas: T or F - ANSWER-True 
 
In MA any newly fired oil burner needs to be inspected by the department of public safety: T or F - ANSWER-False 
 
To wire an oil burner in MA you must be a licensed electrician: T...
- Package deal
- Exam (elaborations)
- • 4 pages •
The heat anticipator in a thermostat is adjusted by the millivolts of the secondary circuit: T or F - ANSWER-True 
 
In MA 527CMR4.00 all electrical safety switches are wired in series: T or F - ANSWER-True 
 
A power venter is an electrically operated mechanical fan to exhaust combustion gas: T or F - ANSWER-True 
 
In MA any newly fired oil burner needs to be inspected by the department of public safety: T or F - ANSWER-False 
 
To wire an oil burner in MA you must be a licensed electrician: T...
HVAC Residential Oil Burners Chpt. 1-8 Exam Questions & Answers(SCORED A+)
boiler heats up hot water w/ a series of piping and circulates it - ANSWER-How does a hot water heating system operate? 
 
Uses a burner to heat the heat exchanger and uses a blower to blow across heat exchanger to travel to air duct work - ANSWER-How does a warm air heating system operate? 
 
1. propane (LP) 
2. coal 
3. fuel oil - ANSWER-What are three types of fossil fuel? 
 
wax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored ou...
- Package deal
- Exam (elaborations)
- • 4 pages •
boiler heats up hot water w/ a series of piping and circulates it - ANSWER-How does a hot water heating system operate? 
 
Uses a burner to heat the heat exchanger and uses a blower to blow across heat exchanger to travel to air duct work - ANSWER-How does a warm air heating system operate? 
 
1. propane (LP) 
2. coal 
3. fuel oil - ANSWER-What are three types of fossil fuel? 
 
wax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored ou...
Mass oil burner / NFPA 31 & NORA Exam Questions and Answers(RATED A)
Cast iron fittings can be used in heating fuel systems? - ANSWER-False 
 
Tank vent shall terminate - ANSWER-Within 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have - ANSWER-Top supply connection 
 
Fuel return piping from an appliance shall - ANSWER-Enter the top of the tank 
 
Oil appliances burning used oil shall only be installed - ANSWER-In commercial or industrial occupancies 
 
Technician must be present for filling of new oil tank - ANSWER-False 
 
A...
- Package deal
- Exam (elaborations)
- • 19 pages •
Cast iron fittings can be used in heating fuel systems? - ANSWER-False 
 
Tank vent shall terminate - ANSWER-Within 12 feet of the fill and visible from the fill 
 
Tanks exceeding 330 gallons must have - ANSWER-Top supply connection 
 
Fuel return piping from an appliance shall - ANSWER-Enter the top of the tank 
 
Oil appliances burning used oil shall only be installed - ANSWER-In commercial or industrial occupancies 
 
Technician must be present for filling of new oil tank - ANSWER-False 
 
A...
Oil Burners for Heating Boilers Exam Questions & Answers(GRADED A)
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75 degrees C - ANSWER-b 
 
An air atomizing burner utilizes an air pressure of 
approximately 
 
a) 15 kPa 
 
b) 150 kPa 
 
c) 75 kPa 
 
d) 95 kPa 
 
e) 100 kPa - ANSWER-e 
 
An air atomizing compressor...
- Package deal
- Exam (elaborations)
- • 9 pages •
The reducing of oil into very small particles is termed 
 
a) fluidization 
 
b) fractionation 
 
c) turbulence 
 
d) atomization 
 
e) distillation - ANSWER-d 
 
Before atomization can occur, heavy oils are heated to 
approximately 
 
a) 203 degrees C 
 
b) 95 degrees C 
 
c) 115 degrees C 
 
d) 75 degrees C - ANSWER-b 
 
An air atomizing burner utilizes an air pressure of 
approximately 
 
a) 15 kPa 
 
b) 150 kPa 
 
c) 75 kPa 
 
d) 95 kPa 
 
e) 100 kPa - ANSWER-e 
 
An air atomizing compressor...
Oil burner components Exam Questions & Answers Graded 100%
Oil Burner Motor - ANSWER-Drives the blower wheel and fuel pump by means of a shaft coupling, spins at 3600rpms 
 
Squirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank, increases pump pressure to 100/140 psig 
 
Cad Cell - ANSWER-A device containing cadmium sulfide used to prove the flame in an oil-burning furnace 
 
Transformer/igniter - ANSWER-Increases voltage 1...
- Package deal
- Exam (elaborations)
- • 2 pages •
Oil Burner Motor - ANSWER-Drives the blower wheel and fuel pump by means of a shaft coupling, spins at 3600rpms 
 
Squirrel Cage - ANSWER-Cylinder shaped fan assembly used to move air 
 
Coupling - ANSWER-A device for joining 2 fluid-flow lines 
 
Oil Pump - ANSWER-Transfers oil from the supply tank, increases pump pressure to 100/140 psig 
 
Cad Cell - ANSWER-A device containing cadmium sulfide used to prove the flame in an oil-burning furnace 
 
Transformer/igniter - ANSWER-Increases voltage 1...
Oil burner 2 Exam Questions and Answers 100% Accurate
SSU - ANSWER-Say bolt both seconds universal 
 
Carbon residue - ANSWER-Amount of carbon left in a sample of oil after boiling oxygen-free atmosphere 
 
Pour point - ANSWER-Lowest temperature at which the fuel can be stored and handled 
 
Ash content - ANSWER-Amount of non combustible materials contained in the fuel oil 
 
Distillation quality - ANSWER-Describes ability of the oil to be vaporized, lighter oil turns into vapor easier than heavy oil 
 
Tank sizes - ANSWER-Tanks are available from ...
- Package deal
- Exam (elaborations)
- • 4 pages •
SSU - ANSWER-Say bolt both seconds universal 
 
Carbon residue - ANSWER-Amount of carbon left in a sample of oil after boiling oxygen-free atmosphere 
 
Pour point - ANSWER-Lowest temperature at which the fuel can be stored and handled 
 
Ash content - ANSWER-Amount of non combustible materials contained in the fuel oil 
 
Distillation quality - ANSWER-Describes ability of the oil to be vaporized, lighter oil turns into vapor easier than heavy oil 
 
Tank sizes - ANSWER-Tanks are available from ...
Oil Burner Exam Questions and Answers 100% Correct
Atomizing type burners were designed to burn which type of fuel? - ANSWER-No. 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by: - ANSWER-All of the above - relocating the outside fuel filter and strainers to the inside , switching to No. 1 fuel oil, reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil 
 
A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room with 5' of heating unit 
 
The primary purpo...
- Package deal
- Exam (elaborations)
- • 8 pages •
Atomizing type burners were designed to burn which type of fuel? - ANSWER-No. 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by: - ANSWER-All of the above - relocating the outside fuel filter and strainers to the inside , switching to No. 1 fuel oil, reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil 
 
A fuel oil storage tank cannot be installed: - ANSWER-In the furnace room with 5' of heating unit 
 
The primary purpo...
Wall Street Prep Exam Bundle GRADED A+!!
Wall Street Prep Exam Bundle GRADED A+!!
- Package deal
- • 10 items •
- WallStreetPrep: Excel Crash course Exam Questions & Answers 100% Accurate • Exam (elaborations)
- Excel Crash Course Exam Questions & Answers 100% Accurate • Exam (elaborations)
- Wall Street Prep: Excel Exam Questions & Answers(RATED A+) • Exam (elaborations)
- Wall Street Prep; Excel Crash Course Formulas Explained Exam With Complete Solutions! • Exam (elaborations)
- Wall Street Prep: Excel Crash Course Formulas Exam Questions & Answers 100% Pass • Exam (elaborations)
- And more ….
Wall Street Prep Exam Bundle GRADED A+!!
Illinois Exam Pack 2024 RATED!!
Illinois Exam Pack 2024 RATED!!
- Package deal
- • 18 items •
- Illinois CNA State exam D Questions & Answers 100% Correct • Exam (elaborations)
- CNA State Exam IL 2023 study With Complete Solutions! • Exam (elaborations)
- IL CNA Practice Exam Questions and Answers 100% SOLVED • Exam (elaborations)
- Illinois CNA Course Quiz #1Exam Questions and Answers(RATED A+) • Exam (elaborations)
- Illinois CNA Course Quiz #1Exam Questions and Answers(RATED A+) • Exam (elaborations)
- And more ….
Illinois Exam Pack 2024 RATED!!
Milady Standard Barbering Exam Review: Ch 18 Hair Coloring and Lighting Questions & Answers Verified by Experts
Awesome
FDNYC G60 Practice Exam Questions & Answers 100% Accurate
Home Health Aide Exam 2023-2024 Questions and Answers 100% Correct!!
Guardianships Exam Questions and Answers 100% Verified
ASU BIO 202: Exam 1 Questions and Answers Solved 100%